| Items |
35.470 (DN 25) 1" 495 lbf STEVI® 470-ANSI Control Valve with Electric Actuator ARI-PREMIO |
35.470 (DN 40) 1 1/2" 495 lbf STEVI® 470-ANSI Control Valve with Electric Actuator ARI-PREMIO |
35.470 (DN 50) 2" 495 lbf STEVI® 470-ANSI Control Valve with Electric Actuator ARI-PREMIO |
35.470 (DN 80) 3" 495 lbf STEVI® 470-ANSI Control Valve with Electric Actuator ARI-PREMIO |
35.470 (DN 100) 4" 495 lbf STEVI® 470-ANSI Control Valve with Electric Actuator ARI-PREMIO |
|||||
| Model No. | N/A 470-ANSI | |||||||||
| Dia. Nominal | N/A 1 Inch | N/A 1 1/2 Inch | N/A 2 Inch | N/A 3 Inch | N/A 4 Inch | |||||
| Dia. Nominal | N/A 25 mm | N/A 38 mm | N/A 51 mm | N/A 76 mm | N/A 102 mm | |||||
| Actuator | N/A ARI-PREMIO 495 lbf | |||||||||
| Flanges | N/A ANSI B16.5 | |||||||||
| Standard Seat Dia. | N/A 0.98 Inch | N/A 1.57 Inch | N/A 1.97 Inch | N/A 3.15 Inch | N/A 3.94 Inch | |||||
| Standard Cv-Value | N/A 12 | N/A 29 | N/A 46 | N/A 116 | N/A 185 | |||||
| Standard Travel | N/A 0.79 Inch | N/A 1.18 Inch | N/A 1.18 Inch | N/A 1.18 Inch | N/A 1.18 Inch | |||||
| Operating Time | N/A 53 sec. | N/A 79 Standard sec.53 sec. | N/A 53 sec.79 sec. | N/A 79 sec. | N/A 79 sec. | |||||
| Weight | N/A 35.1 lbs | N/A 52.7 lbs | N/A 57.1 lbs | N/A 101.2 lbs | N/A 157 lbs | |||||
| Height [H] | N/A 23.1 Inch | N/A 24.3 Inch | N/A 24.3 Inch | N/A 25.5 Inch | N/A 25.6 Inch | |||||
| Valve Dimension [L] | N/A 7.75 Inch | N/A 9.25 Inch | N/A 10.5 Inch | N/A 12.5 Inch | N/A 14.5 Inch | |||||
| Flange Dimension- Ø K | N/A 3.5 Inch | N/A 4.5 Inch | N/A 5.0 Inch | N/A 6.62 Inch | N/A 7.88 Inch | |||||
| Flange Dimension- Ø D | N/A 4.88 Inch | N/A 6.12 Inch | N/A 6.5 Inch | N/A 8.25 Inch | N/A 10 Inch | |||||
| Flange Dimension- n x Ø d1 | N/A 4 x 0.75 Inch | N/A 4 x 0.88 Inch | N/A 8 x 0.75 Inch | N/A 8 x 0.88 Inch | N/A 8 x 0.88 Inch | |||||
| Connection | N/A Option: FormRTJ Standard: FormRF | |||||||||
| Rangeability | N/A 50 : 1 on parabolic plug | |||||||||
| Actuator Motor | N/A 230V 50/60 Hz 24V 50/60 Hz 115V 50/60 Hz | |||||||||
| Guiding | N/A Parabolic Plug: Post Guiding Perforated / V-Port Plug: Post and Port Guiding | |||||||||
| Stem Sealings | N/A Spring loaded PTFE-V-Ring unit PTFE-/ pure graphite-packing Bellows Seal with safety stuffing box | |||||||||
| Flow Characteristic | N/A Linear or equal percentage (from Cv 116 modified equal percentage) | |||||||||
| Shut off Class | N/A Metal Seat - Leakage Class IV acc. To ANSI / FCI 70-2 Soft seat - Leakage Class VI acc. to ANSI / FCI 70-2 (from Cv 1.2) | |||||||||
|
|
||||||||||